Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 Version

Date

Notes

v5.0.9

November 16, 2021

Fixes jogging increment bug in UI.

v5.0.8

November 11, 2021

Generates calibration file on first boot for v2 machines shipped prior to September 2019

v5.0.7

November 10, 2021

  • Added Status Panel

  • Generates calibration file on first boot for v1 machines.

  • Bug fixes

v5.0.0

November 1, 2021

Official release of Kinetic Control.

  • TCPC Support

  • Continuous rotary axis unwinding

  • Full system, atomic updates.

  • New modern, mobile-friendly user interface.

See here for more information.

NOTE: The above software versions (v5.0.0 and up) are only applicable to the Kinetic Control software and user interface.

v4.8.1

April 8, 2021

A minor change to the update process to prevent the possibility of breaking the ability to connect to a host computer over USB.

Click here to download file for update over USB

v4.8.0

March 31, 2021

Added rotated work offsets (RWO).

RWO allows work offsets to be used in your 3+2 machining operations so that you can avoid programming about the center of rotation of the machine. Instructions on how to use RWO can be found here.

Click here to download file for update over USB

v4.7.9

March 10, 2021

The USB download file will now contain any external (i.e. not created or maintained by Pocket NC) software files which need to be downloaded during the normal update process. If no internet connection is available during the update, these files will be used for installation.

Bugfix, removes a configuration value that was undesirably forcing the default network gateway to a route which didn’t allow internet connection. This restores normal behavior, where the machine attempts to automatically set the proper gateway.

Click here to download file for update over USB

v4.7.8

January 21, 2021

Bugfix for changes made in v4.7.6, prevents MAC address from changing on reboot.

Info

This update may take longer than usual. Either allow at least 10 minutes before resuming use, or else verify when the machine has rebooted by watching for the front panel LEDs to toggle off.

Info

The changes in this update will not take effect unless the Pocket NC has internet access while the update is applied.
Applying the update while offline will not cause any changes to the machine’s behavior.

Click here to download file for update over USB

v4.7.7

December 3, 2020

Minor bugfix, prevents Machinekit from crashing upon SSH disconnect.

Click here to download file for update over USB

v4.7.6

November 19, 2020

Updates the ethernet-over-USB protocol used to connect with macOS computers via USB cable. Version 11 of macOS (Big Sur) has removed support for the protocol used previously.

Info

Changes made in this update are only needed for Mac users wishing to connect via USB.

Info

The changes in this update will not take effect unless the Pocket NC has internet access while the update is applied.
Applying the update while offline will not cause any changes to the machine’s behavior.

Info

If your Pocket NC was produced before August 2019
Machines produced prior to August 2019 have an older operating system version that is not compatible with the new protocol. If you are a Mac user with such a machine, please contact our service department.

/wiki/spaces/PNS/pages/185368617

v4.7.5b

November 9, 2020

Bug fix for V2-50s. Prevents situations where the warmup routine could be prematurely terminated without giving an alert, while leaving the spindle turning.

This version was originally released as v4.7.5, but it needed a patch so this was revised to v4.7.5b.

Click here to download file for update over USB

v4.7.4

October 14, 2020

Allows the calibration overlay to set the value of parameters that are also set by an enabled feature.

Click here to download file for update over USB

v4.7.3

August 21, 2020

Bug fix for previous release (there was a typo that prevented those changes from having any effect).

Click here to download file for update over USB

v4.7.2

August 17, 2020

Fixes bug where the HAL component that reads the V2-50 sensors sometimes failed to stop when services restarted, which would result in multiple instances and cause the pressure sensor to become unresponsive.

Click here to download file for update over USB

v4.7.1

August 6, 2020

  • Multiple Rockhopper changes. Small performance gains. Improved logging. Implements async command response and async status items.

  • Can now upload new programs while a program is running.

  • Bugfix, correct jogging increments while in metric units and using UI buttons.

Click here to download file for update over USB

v4.7.0

July 27, 2020

Major performance improvements. Jogging and other commands should be much more responsive. Multiple tabs/devices can be connected at one time without significant performance problems.

Click here to download file for update over USB

v4.6.3

July 17, 2020

  • Improved Rockhopper performance by changing most INI reads to use a cached version of the file instead of reading from disk.

  • Hide tooling options widget on V1 machines (as they don’t have a tool probe button, so the options don’t apply).

Click here to download file for update over USB

v4.6.2

July 3, 2020

Fixed service restart sometimes creating duplicate HAL components.
Click here to download file for update over USB

v4.6.1

July 1, 2020

Fixes issue that prevented USB drives from auto mounting.

Click here to download file for update over USB

v4.6.0

June 23, 2020

  • Can update software version using USB drive.

  • Added indicators to each axis in DRO to let users know when offsets are in place.

  • Can toggle M6 tool probe feature through the UI’s Tooling page.

v4.5.3

May 14, 2020

  • UI file browser no longer opens upon connecting to Rockhopper

  • The UI pause button now works during MDI moves (such as tool probing)

v4.5.2

May 7, 2020

Fix for bug that had broken the ability to restart services from the server configs System page.

v4.5.1

Mar 20, 2020

Allow web socket connections from sub domains of pocketnc.com

v4.5.0

Mar 18, 2020

  • Usability improvements around keyboard jogging.

  • Fix for offset values being initially incorrect right after startup.

v4.4.0

Feb 25, 2020

Several usability improvements related to the Server Config page.

v4.3.1

Feb 20, 2020

Bug fix for previous release, corrects "Run From" button being stuck in disabled state on V2-10s.

v4.3.0

Feb 19, 2020

  •  USB drive feature enables use of external storage device for G-Code programs.

  • Performance improvements.

 v4.2.0

Aug 29 2019

  • Safety switch functionality added.

  • Runtime clock that tracks cumulative time interpreter active when starting a new program or MDI command.

  • Improved display of max-velocity, feed, and spindle values in Run. Override conditions,  pure rotational motion, inverse time mode, and units per rev mode accounted for.

  • Graphs that display previous hour of V2-50 pressure/temperature readings added.

  • Ability to create and enable a swap file through the UI. A swap file allows disk space to be used as additional memory if primary memory is filled. Enabling this will help prevent system slow-downs or crashes when memory usage is high.

v4.1.3

May 10, 2019

More V2-50 fixes. Raised temperature limit and stopped tool probe routine from looping

v4.1.2

Apr 12, 2019

Bug fix. G54 offset properly account for when tool probing.

 v4.1.1

Apr 5, 2019

 Fixed several bugs related to V2-50 pressure and temperature sensors. Fixed bug that prevented newly uploaded G-Code program from automatically opening in some situations.

v4.1.0

Mar 29, 2019

Integrated V2-50 pressure and temperature sensors. This stops the high-precision spindle from operating without an air supply or outside its designed temperature range. Also added a shorter 10 minute warmup cycle for the V2-50 that is required after 12 hours idle, and raised the idle time before the full warm up is required to 7 days.

v4.0.1

Mar 5, 2019

Fixed mouse wheel jogging bug where metric increments were being interpreted as imperial.

v4.0.0

Feb 19, 2019

Improved G code program upload/download Prior versions of the UI could only handle files about 2.5MB in size. With this update the UI can handle files over 100MB in size with upload and download indicators to show progress. This allows the Pocket NC to handle programs with millions of lines of G code.

 

Spindle clocking For machines with the necessary hardware (machines released around June 2018), the measured spindle speed will be shown in the DRO panel. If the machine doesn't have the necessary hardware (the V1 and V2's released prior to June 2018), the DRO will show the commanded speed with any spindle speed overrides applied.

 

Improved metric jogging increments The Jog widget now has sensical fixed step sizes when in metric mode (1mm, .1mm, .01mm and .001mm).

 

Improved MDI interface An indicator was added to the MDI input to show when an MDI command was actually sent to the Pocket NC (a green check indicates the command was successfully sent to the Pocket NC). Better error notifications are shown when MDI commands are not successful or are not able to be sent.

 

Improved Work Offsets panel Fixed bugs with the Work Offsets panel that would trigger a refresh of the UI and/or to improperly set work offsets.

 

Improved workflow for connecting over ethernet The Pocket NC can be connected to a network using its ethernet port, which is required to receive updates. You can also connect to the Pocket NC UI over the network, but it required changing settings in the Conf tab for it to work. Now you can connect to the Pocket NC UI without needing that extra step.

v3.7.0

Sept 13, 2018

Added a status button to the configuration tab to remove programs and big log files from the Beaglebone Board

v3.3.0

July 15, 2018

Removed unnecessary Power and Stop buttons, renamed Shutdown to E-Stop and added a power button for properly shutting down the beaglebone

v3.2.0

July 5, 2018

Improved the compensation table UI for added flexibility in calibrating a machine

v3.1.0

July 4, 2018

Added the ability to upload and download the machine specific calibration data.

v3.0.0 and v3.0.1

June 2018

Fixed bug that caused UI to freeze if changing tabs after running a program.

V2.0.1-beta-9 and 10

May 2018

Fixed tool table issues with units set to mm. Added A and B compensation tables to Linux CNC settings.

v2.0.1-beta-8

January 2018

Fix to prevent freezing when large files are loaded.

v2.0.1-beta-7

Nov 2017

Fixed scrolling and better program line number following.

V2.0.1-beta-3 -6

Oct 2017

Can use tool probe after running a program. Fixed ability to delete files before loading a file, fixed update script to properly call pre- and post-scripts.

...